05 22 40 00 98
contact@promat.ma

Robinetterie industrielle

Détendeurs

Steam Pressure Reducing Valve

Pressure reducing Valves (PRV) are designed for regulating downstream pressure and maintaining it within certain acceptable limits. Ideally, a PRV should provide constant downstream pressure while delivering the required flow, i.e. the PRV automatically adjusts the steam flow to meet the downstream system demand.
MIYAWAKI's pressure reducing valves are designed only for steam.

Types:

Direct acting pressure reducing valves RE1, REC1 and RE2
Pilot operated pressure reducing valves RE3 and RE10N

Specification:
Model Available
Sizes
Available
Connections
Maximum
Operating
Pressure
MPa (psig)
Maximum
Operating
Temperature
°C (°F)
Secondary
Pressure
Range
MPa (psig)
Body and
Cover Material
Download
DIRECT ACTING PRV
RE1 1/2"- 1" Screwed
Rc & NPT
1,6
(230)
204
(399)
0,05-1,0
(7-145)
Brass Télécharger
RE2 3/8" 1,0
(145)
184
(363)
0,1-0,5
(14-72)
REC1 1/2" – 1" Screwed
Rc & NPT
1,6
(230)
220
(428)
0,02-1,0
(2,9-145)
Stainless Steel Télécharger
REC1F DN15-25 Flanged
JIS, ASME, DIN
1,6
(230)
220
(428)
0,02-1,0
(2,9-145)
PILOT OPERATED PRV
RE3 1/2"-2" Screwed
Rc, NPT
1,6
(230)
220
(428)
0,03-1,2
(4,4-174)
Brass Télécharger
RE10N DIN DN15-50 Flanged
JIS, ASME, DIN
1,6
(230)
220
(428)
0,03-1,2
(4,4-174)
Ductile
Cast Iron
Télécharger
RE20 1/2"-8" Flanged
DIN-EN, ASME
1,5
(218)
350
(662)
0,05-1,4
(7.3-203)
Ductile
Cast Iron
Télécharger
REH20 1/2"-8" Flanged
DIN-EN, ASME
2,8
(406)
400
(752)
0,05-1,6
(7.3-230)
Cast
Steel
Télécharger
REC20 1/2"-8" Flanged
DIN-EN, ASME
2,9
(420)
400
(752)
0,05-1,6
(7.3-230)
Stainless
Steel
Télécharger

Operating principle - General

The direct acting PRV has 3 essential elements:

A - Main Valve Unit
B - Pressure Measuring Element (Bellows)
C - Adjust Spring


Operating principle - General

The pilot operated PRV has 4 essential elements:

A - Main Valve Unit
B - Pilot Valve (same structure as the direct-acting PRV)
C - Adjusting Unit (piston and cylinder liner)
D - Signal Line


Changes in downstream pressure are sensed by the bellows, which expands or contracts depending on the pressure change.

The movement of the bellows will be directly transferred to the spring, which will open or close the main valve, thus keeping the downstream pressure at a certain level.

Changes in downstream pressure are sensed by the pilot valve mechanism (bellows connected with a pilot valve unit) through a signal line D, which connects the pilot valve regulator with the secondary pressure side.

Movement of the bellows will open or close the pilot valve, regulating the amount of steam influencing the movement of the piston, which will close or open the main valve, thus keeping downstream pressure on a stable level.

Operating principle - Pilot Operated PRV RE3 & RE10N

Before adjusting the secondary pressure the green handle must be turned clockwise to relea se the adjust spring No.15 until the handle moves freely. In this position the main valve (4) is closed by the force of the spring No. 6 and the pilot valve (11) is closed by the force of the spring No. 13. When steam enters the valve, part of the steam enters the pilot chamber (X) through the orifice (Y).

To adjust the secondary pressure the handle must be turned counterclockwise. As a result, the adjust spring (15) will be pressed into the bellows (14). The bellows will expand and the pilot valve shaft (47) will open the pilot valve (11). The steam, which has entered the pilot chamber (X) will flow through the pilot valve unit into the chamber above the piston (7). Due to the steam pressure the piston (7) will move downwards and open the main valve (4). Steam will flow towards the secondary side.

Part of the steam, which flows to the secondary side will enter the pressure sensing chamber (Z) through the pressure signal line (D). Due to the pressure influence, the bellows (14) will contract. Depending on the secondary pressure value the force exerted by the bellows and the force exerted by the adjust spring (15) will be balanced and the opening degree of the pilot valve (11) will be adjusted, thus regulating the amount of steam flowing through the pilot valve to the piston. Consequently, the opening degree of the main valve (4) will be also adjusted to regulate the steam flow in the direction of the secondary side maintaining a stable steam flow and steam pressure on the secondary side.


Qu'en pensent nos clients?


Nous avons beaucoup apprécié votre disponibilité en temps et en explications.

Reda BENJALOUNE
Mars 2017

L'équipe de PROMAT, par son professionnalisme et son expertise, a su nous conseiller et nous proposer les options adéquates et personnalisées pour mener à bien notre projet.

Hadi MALKI
Juin 2015

Nous apprécions depuis longtemps les bonnes relations que nous entretenons avec l'équipe commerciale de PROMAT.

Imane BOULAHLOUL
Mars 2017

Entreprise sérieuse avec un bon service commercial et un service client très réactif.

Adil LAMRABET
Avril 2014

Nos partenaires

Chez PROMAT INDUSTRIEL DU MAROC, nous veillons en permanence à conserver une relation privilégiée avec les fabricants afin de vous proposer le meilleur service, le meilleur suivi et la meilleure qualité de produits
Nous sommes à votre disposition en magasin, par e-mail ou par téléphone

25, rue de la Participation,
Roches noires - CASABLANCA

05 22 40 00 98

05 22 40 00 89

contact@promat.ma

Qui Sommes-nous ?

Fort de plus de quinze années d’expérience et d’expertise PROMAT est au Maroc un des acteurs majeurs dans les domaines de la robinetterie industrielle, du traitement des eaux, des pompes, des instruments de mesure et du diagnostic et dimensionnement du réseau vapeur.

Notre structure est dotée de moyens performants, renforçant notre compétitivité et l’écoute indispensable de nos clients, pour ainsi saisir le sens de leurs exigences et de répondre à leurs problématiques.

Copyright © PROMAT 2013 Tous droits réservés.
Conception et Création: IKLAM MEDIA